Cabinet material: 1.0mm cold-rolled steel plate, with a surface thickness of 1.2mm after electrostatic spraying

Capacity: 38L

Pallet layer: 1 layer

Ozone generation: 100mg/h

UV lamp specification: 8W * 1

Power supply method: British plug direct insertion

Power supply: 220V/50HZ


HK$3,968.00
HK$2,980.00
{{shoplineProductReview.avg_score}} {{'product.product_review.stars' | translate}} | {{shoplineProductReview.total}} {{'product.product_review.reviews' | translate}}
{{amazonProductReview.avg_rating}} {{'product.product_review.stars' | translate}} | {{amazonProductReview.total_comment_count}} {{'product.product_review.reviews' | translate}}
Quantity Product set quantity
The maximum quantity per submit is 99999
This quantity is invalid, please enter a valid quantity.
Sold Out

Not enough stock.
Your item was not added to your cart.

Not enough stock.
Please adjust your quantity.

{{'products.quick_cart.out_of_number_hint'| translate}}

{{'product.preorder_limit.hint'| translate}}

Limit {{ product.max_order_quantity }} per order.

Only {{ quantityOfStock }} item(s) left.

Please message the shop owner for order details.

Description

Model: 4118

1. Microcomputer control, one click start, automatic disinfection, easy to use.

2. The cabinet body adopts an all steel structure, and the door body is a profile frame tempered glass door. The structure is stable, the sealing is good, and the appearance is beautiful.

3. Adopting advanced processing technology and excellent material selection, the service life of core components is greatly extended, and the internal testing service life is ≥ 8000 hours.

4. Large capacity cabinet and mesh tray ensure the required load-bearing capacity without compromising aesthetics.

5. Disinfection and sterilization have no blind spots, high disinfection efficiency, and stable concentration within the minimum concentration that meets disinfection requirements. After decomposition, there is no secondary pollution.


Packaging list:

Disinfection cabinet


Operating instructions:

1. Connect the power supply to a 220V/50HZ socket with good grounding (the capacity of the power socket should not exceed 10A);

2. Turn on the power switch, the internal system will automatically start, and the display will display the disinfection time set internally. Adjust the disinfection time as needed (recommended: refer to the recommended time in the technical parameter table for disinfection time).

3. After placing the items that need to be disinfected, close the device door, press the power button first, then press the start button to start the device and start working. The display will start counting down.

4. During the disinfection process, if you want to stop the disinfection work, press the "Pause" button. The disinfection work will immediately end, and the device will automatically sound a beep alarm. When the disinfection is paused, the device will automatically return to standby mode,. To reset the disinfection time, press the "Start" button to continue the disinfection work.

5. How to adjust the time? Turn on the power first, then press the start button, and then press pause. Time adjustment can only be made when paused.

6.After the work is completed, in order to extend the service life of the equipment, please turn off the power switch. If it is not used for a long time, please unplug the power plug.


Precautions:

1. The socket must have a reliable grounding wire to ensure safety.

2. The disinfection cabinet must be placed in a dry and ventilated place, away from high temperature, high humidity, and corrosive environments. There should be no flammable materials around it, and it should be at least 20cm away from the wall.

3. When disinfecting items, users should never place the disinfected items at the mouth of the ozone generator to avoid blocking the generator. In severe cases, major liability accidents may occur.

4. When this product is working, it is accompanied by a uniform discharge sound, and there is an ozone odor after opening the door, which is a normal phenomenon.

5.If there is a slight odor of ozone during disinfection, it is a normal phenomenon.

6. If it is necessary to use the disinfection cabinet in a sealed environment, people may feel uncomfortable when the ozone concentration of slight leakage reaches a certain level (depending on their individual bearing capacity), and windows should be opened for ventilation in a timely manner to avoid harm to the body.

7. When disinfecting, it is strictly prohibited to open the door of the disinfection cabinet to prevent the leakage of high concentration ozone and avoid harm to human health.

8.The service life of the ozone generator is greater than or equal to 8000 hours, and the ozone generator must be replaced after the time to avoid affecting the disinfection effect.

9. The maximum design weight of the disinfection rack is 10kg/layer, and the bottom layer is 15kg. When placing disinfection items, be careful not to be overweight, and the number of disinfection items per time should not exceed 2/3 of the cabinet capacity.

10. It is prohibited to use this machine in flammable and explosive places.

11. When the machine is not in use, the power switch must be turned off